Active Power Filter

Next Product »
Yes! I am interested
FOB Price : Get Price

Product Structure:
The Delta PQC Series Active power filter system is constructed of one or several filter modules, with an optional LCM system controller. The filter modules and LCM controller can be embedded in Delta??s standard system cabinet or a third-party cabinet according to user requirements. CT terminations, C-class SPD and breakers are fixed in a standard cabinet, and the APF capacity can be configured according to user requirements. The filter capacity can be easily expanded at the user??s site by plugging in filter modules. Each filter module can filter multi-selected harmonics simultaneously, with reactive power and imbalance compensation by DSP control.
Operation Principle:
The PQC Series APF has a parallel topology between grid side and load side, and can follow and compensate the dynamic harmonic current rapidly. In principle the APF measures harmonic current by CT, and actively calculates each order harmonic current by DSP FFT algorithms, and then it generates a current with phase that is opposite to the measured distorting harmonic current, which cancels out the original harmonics.
The PQC series APF not only eliminates harmonic current from the load side, but it also eliminates grid side harmonic voltage caused by harmonic current, as well as the harm caused by harmonic current and voltage. The APF system can also generate reactive power and imbalance compensation currents, which can cancel existing reactive power and imbalance currents in the system.
Treatment Effect:
Deltas PQC Series APF perfectly eliminates harmonic current and harmonic voltage caused by harmonic current, and ensures the THDu (Total Harmonic Distortion of grid Voltage) < 3%, the THDi (Total Harmonic Distortion of grid current) < 5% and the PF (Power Factor) > 95% with sufficient capacity and low background harmonics. It can also reduce losses and improve the reliability of the power supply system and can also reduce power off loss caused by power quality such as resonance.
PQC Application case: For communication IDC room, as below:
Grid current waveform, value and THDi before and after elimination (record by Fluke 435)
Waveform & Value :It can be seen that current is sinusoidal and value is small after elimination.

RELATED PRODUCTS
 
X

Invalid Input
Please enter Mobile Number
Invalid Email ID
Invalid Email ID
Your Contact Information
Convenient
Competitive Quotes
Choice of Suppliers
Payment Protection
 
sending enquiry ....

unable to instantiate your call right now. please try after some time.

close

©Copyright HelloTrade.com