Stub Cable Type Ee

Next Product »
Yes! I am interested
FOB Price : Get Price

STUB CABLES, without Aluminum Moisture Barrier, Type EE, of Sizes 10, 20, 30, 50 and 100 pairs are used as Stub cables for NCL-type and NFP-type terminal blocks in LME cabinets and distribution points respectively.
General Specification : Saudi Telecom Specification TS -2001 & IEC 60708
Conductor : Solid annealed plain copper wire as per ASTM B 3.
Insulation : Each Conductor shall be covered with continuous layer of Solid High Density Polyethylene. Color of Insulation as per Table-1 & Table-2.
Assembly : Two Insulated conductors twisted together to form a pair. 10 Pairs are assembled to form a sub-unit. Up to 100 pairs, these sub-units are assembled to form the cable. The Final Assembly is covered with non-hygroscopic tape.
Moisture Barrier : Aluminum Tape, coated on both sides with co-polymer as per ASTM B 736, is applied longitudinally with a suitable overlap to prevent the ingress of water to the cable.
Sheath : Extruded black Linear Low Density Polyethylene, as per ASTM D 1248, continuously bonded to the aluminum tape to prevent of water penetration to the core and the transport of water between the sheath and the tape.

RELATED PRODUCTS
 
X

Invalid Input
Please enter Mobile Number
Invalid Email ID
Invalid Email ID
Your Contact Information
Convenient
Competitive Quotes
Choice of Suppliers
Payment Protection
 
sending enquiry ....

unable to instantiate your call right now. please try after some time.

close

©Copyright HelloTrade.com