Welcome to HelloTrade!
I Want to Buy
Request for Quote
Member
Since
7 Yrs
4114 North Ravenswood Avenue
Chicago, Illinois-60613, United States+(1)-773-3274520
Contact Supplier

Solar Simulation Chamber (Mh/Mhg)

Next Product »
Yes! I am interested
FOB Price : Get Price

Full Function climatic chamber with additional simulation of the global sunlight spectra. With a capacity of 600 l, the test chamber is designed for testing medium-sized components.

  • Radiation source: Metal Halide Lamp, 1 x 1500 W (Type MH); 1 x 2500 W (Type MHG)
  • Chamber volume: 800x800x965 mm (WxDxH)
  • Filter system: Outdoor/Indoor
  • Irradiance: 1000 W/m2 )Type MH); 800 to 1500 W/m2 (Type MHG)
  • Spectral distribution: Global radiation, 280-3000 nm (Base: CIE No.85, Table 4; Share: DIN 75220, Table 1, Column 2/4)
  • Temperature ranges: w/ irradiation -20 °C to 100 °C, w/o irradiation -30 °C to 100 °C
  • Heating rate 4.0 K/min
  • Cooling rate 2.5 K/min
  • Touch control panel
  • Micro-processor monitoring and control unit SIMCON/32
  • Digital customer I/O, potential-free 24 V, 4 freely disposable inputs/outputs
  • Independent adjustable temperature limiter tmin / tmax
  • Adjustable software temperature limiter min./max.
  • Humidity input and display in % rel. humidity
  • Centronics printer interface
  • Serial interface RS 232
  • European Socket
  • Calibration of 2 temperature values and 2 climate values
  • Air-cooled refrigeration unit
  • Condensation protection (dehumidification during heating phase)
  • Aerosol-free humidification and dehumidification
  • Psychrometric humidity measuring system
  • Water supply tank for humidification water with level indication
  • Automatic water replenishment with low water alarm
  • 1 Entry port, NW 50 mm, left-hand side
    1 Entry port, NW 125 mm, right-hand side
  • 1 Shelf made of stainless steel
  • Radiation unit with metal halid lamp 1 x 2 kW
  • 1 Set of operating instructions

Solar Simulation Chamber (Mh/Mhg)

Solar Simulation Chamber (Mh/Mhg)

Get Quotes
Yes! I am interested
FOB Price : Get Price

Full function climatic chamber with additional simulation of global sunlight spectra. With its 1000 l test chamber, the SC1000 is perfectly designed to test mid to large size components.

  • Radiation source: Metal Halide Lamp, 2 x 1500 (Type MH) ; 1 x 2500 W (Type MHG)
  • Chamber volume: 1100 x 950 x 950 mm (WxDxH)
  • Filter system: Outdoor/Indoor
  • Irradiance: 1000 W/m2 (Type MH); 800-1200 W/m2 (Type MHG)
  • Spectral distribution: Global Radiation 280 ? 3000 nm (Base: CIE, Table 4; Share: DIN 75220, Table 1, Column 2/4)
  • Temperature ranges w/ radiation: -20 °C to 100 °C
  • Temperature ranges w/o radiation ?30 °C to 100 °C
  • Heating rate: 4.0 K/min
  • Cooling rate: 2.5 K/min
  • Touch control panel
  • Micro-processor monitoring and control unit SIMC ON/32
  • Digital customer I/O, potential-free 24 V, 4 freely disposable inputs/outputs
  • Independent adjustable temperature limiter tmin / tmax
  • Adjustable software temperature limiter min./max.
  • Humidity input and display in % rel. humidity
  • Centronics printer interface
  • Serial interface RS 232
  • Potential-free contact for switching-off of test specimens
  • European socket
  • Calibration of 2 temperature values and 2 climate values
  • Air-cooled refrigeration unit
  • Condensation protection (dehumidification during heating phase)
  • Aerosol-free humidification and dehumidification
  • Psychrometric humidity measuring system
  • Water supply tank for humidification water with level indication
  • Automatic water replenishment with low water alarm
  • 1 Entry port, NW 50 mm, left-hand side
    1 Entry port, NW 125 mm, right-hand side
  • 1 Shelf made of stainless steel
  • Radiation unit with metal halid lamp 2 x 1.5 kW
  • 1 Set of operating instructions

Solar Simulation Chamber (Mh/Mhg)

Solar Simulation Chamber (Mh/Mhg)

Get Quotes
Yes! I am interested
FOB Price : Get Price

Full Function climatic chamber with additional simulation of the global sunlight spectra. With its 3400 l test chamber, the SC2000 is suited to test large volume finished products or entire component series.

  • Radiation source: Metal Halide Lamp, 4 x 1500 W (Type MH); 2 x 4000 W (Type MHG)
  • Chamber volume: 1995x1150x1510 mm (WxDxH)
  • Filter system: Outdoor/Indoor
  • Irradiance: 1000 W/m2 (Type MH); 800 to 1200 W/m2 (Type MHG)
  • Spectral distribution: Global radiation, 280-3000 nm (Base: CIE No.85, Table 4; Share: DIN 75220, Table 1, Column 2/4)
  • Temperature ranges: w/ irradiation -20 °C to 100 °C, w/o irradiation -30 °C to 100 °C
  • Heating rate 2.0 K/min
  • Cooling rate 1.5 K/min
  • Irradiated area approx. 1.36 m²
  • Touch control panel
  • Micro-processor monitoring and control unit SIMCON/32
  • Digital customer I/O, potential-free 24 V, 4 freely disposable inputs/outputs
  • Independent adjustable temperature limiter tmin / tmax
  • Adjustable software temperature limiter min./max.
  • Humidity input and display in % rel. humidity
  • Centronics printer interface
  • Serial interface RS 232
  • Potential-free contact for switching-off of test specimens
  • European socket
  • Water-cooled refrigeration unit
  • Humdification with steam generator
  • Capacitive humidity measuring system
  • Automatic water replenishment
  • Calibration of 2 temperature values
  • 1 Entry port, NW 80 mm, left-hand side
  • Radiation unit with metal halid lamp 4 x 1.5 kW
  • 1 Set of operating instructions
  • Insulated cover: Expands the temperature range to -40°C to +120°C
  • Misting equipment: Expands the test possibilities in the area of climate
  • UV sensors: 280 nm to 320 nm / 320 nm to 400 nm
  • Control of black standard temperature
  • Black standard temperature sensor
  • Solar test sensor: 300 nm to 3000 nm
  • Printer: 6-color, programmable
  • S!MPATI software for Data Acquisition
  • RS 422/485 interface

Reference Test Specifications include:





Reference Test Specifications include:

  • MIL-STD-810, EPA or others.
  • DIN 75220
    Ageing of automotive componentsin solar simulation units

RELATED PRODUCTS
 
X

Invalid Input
Please enter Mobile Number
Invalid Email ID
Invalid Email ID
Your Contact Information
Convenient
Competitive Quotes
Choice of Suppliers
Payment Protection
 
sending enquiry ....

unable to instantiate your call right now. please try after some time.

close

©Copyright HelloTrade.com