Our organization is trademark provider of Pasteurizer in various specifications and as per industry standards.

Features:

  • Quality approved
  • Flawless
  • Easy to install

Specifications:

Brand Name :Huide

Model Number :HD-SJG

Place of Origin :China

Processing :a variety of food

Processing Types :a variety of food

Size :Customized

The use and maintenance of the sterilization pot

User should be based on the production process of the enterprise and the technical performance of the sterilization pot to formulate the safe operation of the pot, and strictly enforced. The safety operation regulations of the sterilizing pot should be at least including:

  • The operating process and the highest working pressure of the sterilizing pot, the highest working temperature.
  • The operation method and procedure of the sterilization pot and the matters needing attention.
  • The operation of the production should focus on the inspection of the project and the site, as well as the operation of the abnormal phenomenon and prevent measures.
  • Maintenance method when the device is deactivated.
  • 2, the device is strictly prohibited than the design pressure, temperature operation.
  • 3, the use of the operator should be trained to pass the training examination, should strictly abide by the safety operation regulations and post responsibility system; found abnormal phenomenon should be treated in time.
  • 4, Sterilization pot installed with safety valve, pressure gauge, thermometer and other accessories, to keep safe, complete, sensitive and reliable. In the use of the process should be added to the maintenance and periodic calibration. The safety valve of the device is equal to the design pressure, should be sensitive and reliable, and should be prevented at random adjustment. The pressure gauge and the accuracy grade of the thermometer are 1.5 levels, and the tolerance is normal. No seal pressure gauges shall not be used, pressure gauge indication failure, scale is not clear, dial rupture and release pressure after the pointer does not return to zero, seal damage shall be replaced immediately. The thermometer should be inspected on a regular basis, before use should be to standard thermometer calibration, after the annual nuclear Zhengyi times, where the mercury column fracture and to the standard temperature difference exceeds 0.5 DEG C should be repaired or replaced.
  • 5, sterilization pot should be regularly checked, at least once every half a year, the external inspection, at least once a year to conduct a comprehensive inspection, inspection before the preparatory work and inspection items, are in the "Regulations" and the relevant provisions, inspection report filed for the record.
  • 6, in the use of the process should be often inclined self-locking wedge block, a roller, a pot ears, swivel flange sliding and rolling contact parts of smearing grease and oil, to ensure that the friction surface in the lubrication state.
  • 7, pot body flange sealing ring if aging, defect and wear too large, should be replaced in time, in order to ensure the sealing, prevent leakage.
  • 8, the equipment should be stopped, and the inner and outer surface sterilization pot lid clean. Exposed machined surface brush to anti rust paint, safety testing control instrument to cover the protection.

RELATED PRODUCTS
 
X

Invalid Input
Please enter Mobile Number
Invalid Email ID
Invalid Email ID
Your Contact Information
Convenient
Competitive Quotes
Choice of Suppliers
Payment Protection
 
sending enquiry ....

unable to instantiate your call right now. please try after some time.

close

©Copyright HelloTrade.com