Clean fresh waterGeneral It is equipped with low pressure UV-lamps, powered by electronic high frequency ballasts, for highest efficiency and lowest power consumption. The sterilization process is microprocessor-controlled via data from the UV-sensor. The intelligent lamp monitoring system will, in case of any lamp failure, inform the user of this occurrence as well as the location of the broken lamp. The hour meter tells the user to change lamps when the limit of its using time is reached. All necessary data is available in a display window on the control cabinet. Flow capacity Maximum flow at different water qualities (m³/h). Normally the Max/Min capacity of a UV-unit is chosen between T50=90% down to T50=60%. T10=100% T10=98% T10=96% T10=93% T10=90% T10=87% T10=83% Size T50=100% T50=80% T50=80% T50=70% T50=60% T50=50% T50=40% UV1 1.41 1.28 1.15 1.01 0.88 0.74 0.60 UV2 1.98 1.79 1.61 1.42 1.24 1.04 0.85 UV3 4.59 4.05 3.51 3.01 2.53 2.06 1.62 UV4 6.98 6.13 5.30 4.54 3.82 3.13 2.49 UV5 12.49 10.52 8.73 7.17 5.79 4.55 3.45 UV31 15.88 14.00 12.14 10.41 8.75 7.13 5.60 UV41 24.09 21.13 18.28 15.67 13.21 10.86 8.66 UV51 43.20 36.39 30.19 24.82 20.03 15.73 11.94 Technical data Voltage: 110/230 VAC 50/60 Hz Power consumption: 35-290W depending on size UV-dosage: 36000 Ws/cm² Alarm: Open/closed 1A resistive Relay output, normally Working pressure: Max 10 bar Material chamber: Stainless Steel 316L Weight: 15-25 kg (up to sizes)
Main Features Lamp monitoring system LCD display UV-sensor standard Low power consumption Compact design in stainless steel 316L