Microbiological Safety Cabinet Class II, TUV certified to EN 12469 (3,4 & 6 ft (on going)) Sash window type, motorized, with predefined working position and motion control keys at front of side wall Sloped front allowing comfortable standing at work Available with glass or solid side windows Automatic inflatable gasket for chamber sealing - fumigation Back up battery for front window closing after a power failure and power alarm Stainless steel curved armrest at 30mm above bench level Noise level 55 dBA 2 independent blowers and anemometers to control chamber air flow and inlet/exhaust flow Exhaust and chamber HEPA filters H-14 of efficiency 99,995 % MPPS (99,999 % DOP) Microprocessor control with filter clogging automatic compensation Connector for remote PC control with UltraLogger software HEPA filters clogging percentage real time calculation and display ""Turbo exhaust"" function key to increase operator protection

Telstar offers a wide range of Class II Microbiological Safety Cabinets to suit all required configurations and budgets.
Designed according to Class II European standard EN 12469, most versions are TUV certified, from 3 to 6 ft with possible customization.
Unique features like inflatable gasket and remote control put Telstar units at the high end of Class II cabinets. N 12469, AS2253 certified, Bio II A is a class II cabinet range which offers simplicity, robustness and high reliability. Independent blowers with independent anemometers provide excellent air speed control and automatic filter clogging compensation. Available in 4 sizes (3,4,5 and 6 ft). Various accessories and options make the cabinet adaptable to every application. Possible customization.

Telstar offers a wide range of Class II Microbiological Safety Cabinets to suit all required configurations and budgets.
Designed according to Class II European standard EN 12469, most versions are TUV certified, from 3 to 6 ft with possible customization.
Unique features like inflatable gasket and remote control put Telstar units at the high end of Class II cabinets. Third HEPA filter set below the work bench of CytoUltra traps the contaminants thus preventing them reaching the plenum, the main HEPA filter and the HEPA exhaust filter. This reinforced safety is required for the handling of highly toxic compounds. Certified EN 12469 Class II and DIN 12980 for Cytotoxics, CytoUltra offers the most advanced features in product and operator protection and in ergonomics to allow best working conditions. Third filter stage eliminates contamination risks when servicing the unit. Third HEPA filter stage easily replaced in the unit basement and filter clogging calculation minimize maintenance cost and time. Remote PC Ultralogger control suitable for P3 lab.



sending