LP6 Ventilator

Next Product »
Yes! I am interested
FOB Price : Get Price

Our durable LP Series of portble volume ventilator have a repurarion for dependability. They are built with a patented brushes motor.

Front Panel Controls :

  • Mode: Standby, Assist/Control, SIMV or Pressure Cycle
  • Low Pressure Alarm: Set limit for Low Pressure alarm 2 to 32
  • cmH2O in increments of 2 cmH2O
  • High Pressure Alarm Limit: (Assist/Control, SIMV Modes) or limit
  • For Pressure Cycle mode: 15 to 90 cmH2O in increments of 5 cmH2O
  • Volume: Push-to-turn knob: 100 to 2200 mL
  • Breath Rate: 1 to 20 BPM in increments of 1 BPM and 22 to 38

Inspiratory Time: 0.5 to1.0 sec in increments of 0.1 sec;

1.2 sec; and 1.5 to 5.5 sec in increments of 0.5 sec

Breathing Effort: Push-to-turn knob sets pressure level to detect

breathing effort (-10 cmH2O/hPa to +10 cmH2O)

Front Panel Input

Patient Pressure: Port for connection to proximal pressure line of patient circuit


Front Panel Input
Patient Pressure: Port for connection to proximal pressure line of patient circuit


Front Panel Output
Patient Air: 22 mm x 15 mm tube for connection to bacteria filter

Exhalation Valve: Port for connection to exhalation valve of patient circuit


Indicators, Normal Events
Patient Pressure Meter: Displays patient pressure -10 to +100 cmH2O; can also display battery charge and machine hrs of operation
Breathing Effort: Green LED activated by adequate patient breathing effort
Power: LEDs indicate operating power source: green AC Pwr/Batt Chg, amber External Battery, flashing amber Internal Battery
Alarms: Flashing red LEDs: Low Pressure/Apnea, Low Power, High Pressure, Setting Error, Power Switchover


Audible Alarms
Pulsating Tone: Low Pressure/Apnea; Low Power, High Pressure, Setting Error, Power Switchover
Steady Tone: Loss of microprocessor control
Reminder Tone: Every 5 mins when powered by Internal Battery,each time accessory printer generates report


Rear Panel Controls
AC Circuit Breaker: Internal to AC power switch(1 for ON; 0 for OFF)


Rear Panel Inputs
Inlet Filter: Intake for patient air; screw off cap for filter change
External Battery: Connection for 12 VDC battery Communication Port: Calibration information during service procedure

RELATED PRODUCTS
 
X

Invalid Input
Please enter Mobile Number
Invalid Email ID
Invalid Email ID
Your Contact Information
Convenient
Competitive Quotes
Choice of Suppliers
Payment Protection
 
sending enquiry ....

unable to instantiate your call right now. please try after some time.

close

©Copyright HelloTrade.com