Our durable LP Series of portble volume ventilator have a repurarion for dependability. They are built with a patented brushes motor.

Front Panel Controls :

  • Mode: Standby, Assist/Control, SIMV or Pressure Cycle
  • Low Pressure Alarm: Set limit for Low Pressure alarm 2 to 32
  • cmH2O in increments of 2 cmH2O
  • High Pressure Alarm Limit: (Assist/Control, SIMV Modes) or limit
  • For Pressure Cycle mode: 15 to 90 cmH2O in increments of 5 cmH2O
  • Volume: Push-to-turn knob: 100 to 2200 mL
  • Breath Rate: 1 to 20 BPM in increments of 1 BPM and 22 to 38

Inspiratory Time: 0.5 to1.0 sec in increments of 0.1 sec;

1.2 sec; and 1.5 to 5.5 sec in increments of 0.5 sec

Breathing Effort: Push-to-turn knob sets pressure level to detect

breathing effort (-10 cmH2O/hPa to +10 cmH2O)

Front Panel Input

Patient Pressure: Port for connection to proximal pressure line of patient circuit


Front Panel Input
Patient Pressure: Port for connection to proximal pressure line of patient circuit


Front Panel Output
Patient Air: 22 mm x 15 mm tube for connection to bacteria filter

Exhalation Valve: Port for connection to exhalation valve of patient circuit


Indicators, Normal Events
Patient Pressure Meter: Displays patient pressure -10 to +100 cmH2O; can also display battery charge and machine hrs of operation
Breathing Effort: Green LED activated by adequate patient breathing effort
Power: LEDs indicate operating power source: green AC Pwr/Batt Chg, amber External Battery, flashing amber Internal Battery
Alarms: Flashing red LEDs: Low Pressure/Apnea, Low Power, High Pressure, Setting Error, Power Switchover


Audible Alarms
Pulsating Tone: Low Pressure/Apnea; Low Power, High Pressure, Setting Error, Power Switchover
Steady Tone: Loss of microprocessor control
Reminder Tone: Every 5 mins when powered by Internal Battery,each time accessory printer generates report


Rear Panel Controls
AC Circuit Breaker: Internal to AC power switch(1 for ON; 0 for OFF)


Rear Panel Inputs
Inlet Filter: Intake for patient air; screw off cap for filter change
External Battery: Connection for 12 VDC battery Communication Port: Calibration information during service procedure