Welcome to HelloTrade!
I Want to Buy
Request for Quote

Single Channel Automatic Electrocardiograph

Next Product »
Yes! I am interested
FOB Price : Get Price

Automatic recording
set to automatic recording mode,the machine can aromatically record standard 12 leads ecg trace whenever two key-trokes is completed. Manual intervention is allowed in the process.
ac/rechargeable battery
the built in battery can guarantee the machine's operation when ac power supply is not available. It will be automatically cut off by ways of a timer,if the machine is set to modeltopithout operation for 2 minutes.
excellent recording system
stylus recording system features linear compensation & position feedback compensation.
unique design of touch-key
completely sealed touch key features waterproof and dust proof as well as easy maintenance.
isolated input circuit
the isolated input circuit complies with iec requirements for safety level of class i type cf,guarantees protection of the machine from possible damage and hazard due to operation of defibrillator and pace maker.
powerful ac & emg filter
specially designed fillers can effectively inhibit ac & emg interference.
multiple recording mode (for ecg-11c only)
the two line lcd can display operation conditions of the machine and such parameters as lead under recording,sensitivity,paper speed,filler status,recording mode and etc.
distinguish among ecg-11a,ecg-11b and ecg-11c
input circuit safety level
ecg-11a isolated and defibrillation protected class i,type cf
ecg-11b not isolated class i,type b
ecg-11c isolated and defibrillation protected class i,type cf
lead fault alarm
ecg-11a able to indicate lead fault and cable disconnection
ecg-11b n/a
ecg-11c able to indicate lead fault and cable disconnection
ac/battery display
ecg-11a automatic changeover and capacity protection led
ecg-11b manual changeover led
ecg-11c automatic changeover and capacity protection lcd
specifications
input circuit: isolated
input circuit current : ≤50na
patient current leakage : ≤10μa
input impedance : ≥50mω
baseline drift : <0. 3mm
calibration voltage: 1mv? %
noise level : ≤15μvp-p
cmrr : ≥100db
frequency response: 0. 05-85hz(-3db)
time constant: ≥3. 2seconds
sensitivity: 5mm/mv,10mm/mv,20mm/mv
paper speed: 5mm/s,25mm/s,50mm/s
power requirements ac: 220v,50hz;110v,60hz
dc: rechargeable battery supporting 50exams
weight: 5kg
package 760x550x450mm for 4 sets in 1 carton;
240x450x370mm for 1 sets in 1 box

Single Channel Automatic Electrocardiograph

Single Channel Automatic Electrocardiograph

Get Quotes
Yes! I am interested
FOB Price : Get Price

Automatic Recording
Set to automatic recording mode,the machine can aromatically record standard 12 leads ECG trace whenever two key-trokes is completed.Manual intervention is allowed in the process.
AC/Rechargeable Battery
The built in battery can guarantee the machine's operation when AC power supply is not available.It will be automatically cut off by ways of a timer,if the machine is set to modelTOPithout operation for 2 minutes.
Excellent Recording System
Stylus recording system features linear compensation & position feedback compensation.
Unique Design of touch-key
Completely sealed touch key features waterproof and dust proof as well as easy maintenance.
Isolated Input Circuit
The isolated input circuit complies with IEC requirements for safety level of class I type CF,guarantees protection Of the machine from possible damage and hazard due to operation of defibrillator and pace maker.
Powerful AC & EMG Filter
Specially designed fillers can effectively inhibit AC & EMG interference.
Multiple Recording Mode (For ECG-11C Only)
The two line LCD can display operation conditions of the machine and such parameters as lead under recording,sensitivity,paper speed,filler status,recording mode and etc.
Distinguish Among ECG-11A,ECG-11B and ECG-11C
Input Circuit Safety Level
ECG-11A Isolated and defibrillation protected Class I,type CF
ECG-11B Not isolated Class I,type B
ECG-11C Isolated and defibrillation protected Class I,type CF
Lead Fault Alarm
ECG-11A Able to indicate lead fault and cable disconnection
ECG-11B N/A
ECG-11C Able to indicate lead fault and cable disconnection
AC/Battery Display
ECG-11A Automatic changeover and capacity protection LED
ECG-11B Manual changeover LED
ECG-11C Automatic changeover and capacity protection LCD
SPECIFICATIONS
Input Circuit: Isolated
Input Circuit Current : ≤50nA
Patient Current Leakage : ≤10μA
Input Impedance : ≥50MΩ
Baseline Drift : <0.3mm
Calibration Voltage: 1mV?%
Noise Level : ≤15μVP-P
CMRR : ≥100dB
Frequency Response: 0.05-85Hz(-3dB)
Time Constant: ≥3.2seconds
Sensitivity: 5mm/mV,10mm/mV,20mm/mV
Paper Speed: 5mm/s,25mm/s,50mm/s
Power Requirements AC: 220V,50Hz;110V,60Hz
DC: Rechargeable battery supporting 50exams
Weight: 5Kg
Package 760X550X450mm for 4 sets in 1 carton;
240X450X370mm for 1 sets in 1 box

Single Channel Automatic Electrocardiograph

Single Channel Automatic Electrocardiograph

Get Quotes
Yes! I am interested
FOB Price : Get Price

Specifiacations
Input Circuit : Isolated
Safety Level: Class I,Typa CF
Input Impedance : ≥50MΩ
Input Circuit Current: ≤50nA
Noise Level: ≤15μVP-P
Patient Current Leakage: ≤10μA
CMRR: ≥100dB
Frequency Response: 0.05-150Hz(-3dB)
A/D Constant : 12 bit
Time Constant: >3.2 second
Sampling Rate: 1ms
Dspolarization Voltage : ?00mV
Sensitivity : 5mm/mV,10mm/mV,
20mm/mV,Auto
Paper Speed: 25mm/s,50mm/s
Power Requirements AC: 220V,50Hz,110V,60Hz
DC: Rechargeable
battery supporting: 50 exams
Weight : 3.5Kg
Package: 640X400X530mm for 4 sets
240X310X370mm for 1 set
Features
A High-resolution thermal array printer is used to print clear and accurate waveform on thermal recording paper.
The anti filter is designed to control baseline position and baseline drift.
Automatic lead change.Auto printing of date,time,and parameters including paper speed,sensitivity,filter status,and etc.
Powerful digital filter for effective inhibition of AC and EMG filter
Key-stroke is accompanied with "beep"sound for comfirmation of correct input.
A four line LCD is used to display main menu,AMP menu,status menu and other function menu
Completely charged,the built in battery can support at least 50 exams.
Able to print in two channel mode the normal ECG trace and that of any rhythm lead.
Thermal Printer:Vertical:8dot/mm;Horizontal:40dot/mm(25mm/s);Able to print sensitivity,heart rate,paper speed,filters status,and etc
Heart Rate Measurement