Chemical Earthing

Next Product »
Yes! I am interested
FOB Price : Get Price

We are engaged in offering GI Earthing Electrode, which is widely available at cost-effective range. Our experts thoroughly test these products on certain quality-testing parameters that we instilled in our infrastructure.

These products have gained encored appreciation among our client base owing to certain features listed below:

  • High tensile strength.
  • Dimensional accuracy.
  • Corrosion resistance. Copper Earth/Earthing Electrodes which is manufactured using the most premium quality circular rods of low carbon steel for a high tensile strength and durability. We adhere to the specifications of Underwriters Laboratories (UL) 467-2007 and the copper earthing electrode is accordingly molecularly bonded with the exterior of the rod. It is highly effective and widely appreciated for its functionality among our clients.

    Details:

    · UL

    · Diameter: Minimum 20.0 mm

    · Length: Minimum 1,2,3 meters

    · Copper bonding thickness: 250,500,750,1000 microns,

    · Maintenance free

    · High strength rod

    · Corrosion resistant

    · Low resistance path to earth

    · Cost
  • SELECTION OF EARTH SYSTEM
  • S.N. Installations/ Current Capacity
  • IR Value Required
  • Soil Type/ Resistivity Earth System
  • 1. House hold earthing/ 3kA
  • 8 ohm Normal Soil/ upto 50 ohm-mtr Single Electrode Sandy Soil/ between 50 to 2000 ohm-mtr Single Electrode Rocky Soil/ More than 2000 ohm-mtr Multiple Electrodes
  • 2. Commercial premises Office buildings/ 5kA
  • 2 ohm Normal Soil/ upto 50 ohm-mtr Single Electrode Sandy Soil/ upto 2000 ohm-mtr Multiple Electrodes Rocky Soil/ More than 2000 ohm-mtr Multiple Electrodes
  • 3 Transformers, substation earthing, LT line equipment/ 15kA
  • 1 - 2 ohm Normal Soil/ upto 50 ohm-mtr Single Electrode Sandy Soil/ upto 2000 ohm-mtr Multiple Electrodes Rocky Soil/ More than 2000 ohm-mtr Multiple Electrodes
  • 4 Transformers, substation earthing, HT line equipment/ 40kA
  • less than 1 ohm
  • Normal Soil/ upto 50 ohm-mtr Single Electrode Sandy Soil/ upto 2000 ohm-mtr Multiple Electrodes Rocky Soil/ More than 2000 ohm-mtr Multiple Electrodes
  • 5 Lightning arresters, extra high current applications etc./ 50kA
  • less than 1 ohm
  • Normal Soil/ upto 50 ohm-mtr Single Electrode Sandy Soil/ upto 2000 ohm-mtr Multiple Electrodes Rocky Soil/ More than 2000 ohm-mtr Multiple Electrodes
  • 6 PRS, UTS, RTUs,FOIS, COIS, ATMs and data processing centre etc./5KA
  • less than 0.5 ohm
  • Normal Soil/ upto 50 ohm-mtr Single Electrode Sandy Soil/ upto 2000 ohm-mtr Multiple Electrodes Rocky Soil/ More than 2000 ohm-mtr Multiple Electrodes Note :- Single/multiple electrode in above earth system shall be either rod earth electrode or concentric pipe earth electrode as per clause 8.1.

RELATED PRODUCTS
 
X

Invalid Input
Please enter Mobile Number
Invalid Email ID
Invalid Email ID
Your Contact Information
Convenient
Competitive Quotes
Choice of Suppliers
Payment Protection
 
sending enquiry ....

unable to instantiate your call right now. please try after some time.

close

©Copyright HelloTrade.com