Thermal Cutoffs / Thermal Fuse
SW-1 Series SW-2 Series SW-3 Series SW-5 Series SW-6 Series


SW-1 Series

RATED VOLTAGE : 250V, ac (and 125V)
RATED CURRENT : 10A (and 15A)
INTERRUPTING CURRENT : 250V, ac 15A
TRANSIENT OVERLOAD TEST CURRENT : dc current pulses, with an amplitude 150 A and a duration of 3 ms with 10 s intervals, are applied for 100 successive cycles through the current path.

SW-2 Series
RATED VOLTAGE : 250V, ac
RATED CURRENT : 2A
INTERRUPTING CURRENT : 250V, ac 3A
TRANSIENT OVERLOAD TEST CURRENT :
dc current pulses, with an amplitude 30A and a duration of 3 ms with 10 s intervals, are applied for 100 successive cycles through the current path.


SW-3 Series

RATED VOLTAGE : 250V, ac
RATED CURRENT :15A
INTERRUPTING CURRENT : 250V, ac 22.5A
TRANSIENT OVERLOAD TEST CURRENT :
dc current pulses, with an amplitude 225 A and a duration of 3 ms with 10 s intervals, are applied for 100 successive cycles through the current path.

SW-5 Series

RATED VOLTAGE : 250V, ac (and 125V -*)
RATED CURRENT : 5A (and 6A -*)
INTERRUPTING CURRENT : 250V, ac 7.5A
TRANSIENT OVERLOAD TEST CURRENT :
dc current pulses, with an amplitude 75 A and a duration of 3 ms with 10 s intervals, are applied for 100 successive cycles through the current path.


SW-6 Series

RATED VOLTAGE : 50V, dc
RATED CURRENT : 2A or 4A
INTERRUPTING CURRENT : 50V, dc 3A or 6A

RELATED PRODUCTS
 
X
More Products From This Supplier

Invalid Input
Please enter Mobile Number
Invalid Email ID
Invalid Email ID
Your Contact Information
Convenient
Competitive Quotes
Choice of Suppliers
Payment Protection
 
sending enquiry ....

unable to instantiate your call right now. please try after some time.

close

©Copyright HelloTrade.com