  • Direction of air flow : Follow the arrow direction on  housing, from inside to outside of filter, for installation.
  • Manual drain eliminates water regularly, and steamed by-  pass valve is disposition for selection.
  • Compressed air should be liquid, impurities and oil-free before injecting into the housing, and 3-stages qualified pre-filtration is required for sterile filter.
  • Do sterilization regularly : 1~2 times a week, 20~30 mins each time. Utilizing sterile filter, which is under critical proccess of clean steam with 1 micron rating, ex. steam temperature< 130℃, pressure< 2.5bar. If steamed pressure is higher than designed one, and then pressure reduced valve should be distributed.
  • Used sterile filter must be drying by clean compressed air, and increases pressure by opening valve steadily before reuse.
  • Filter replacement should be done when pressure drop reaches 0.7~1 bar or 50 times steam sterilization.