Digital Yarn Control Time Settings : The Tecatron Piezo-Electric Weft Stop Motion System detects every Yarn Break or Stop over a programmable length, this to control the Yarn motion over the total weft time. A digital extra time can be set after the end signal by the proximity switch, to adjust the total control time. Switch single-double : each of the 8 eyelets can be switched into the single or double control position. - Single: detect every unwanted extra yarn movement into other eyelets from the selected Single eyelet group , for instance if extra yarns are inserted by mistake. - Double : By switching eyelets into the double position, this eyelet group controls that always 2 eyelets are activated during the weaving cycle. If only 1 or more than 2 eyelets are activated, the machine will be stopped automatically. ADVANTAGES Digital Yarn Control Timer Settings to re-adjust control time of the moving yarns Single and Double Yarn Controlling Very fast reaction time Ceramic eyelets with high wearing resistance properties No additional loads on the weft Yarns Detector housing of robust CNC-mill Aluminum Din-rail mounting Controller Unit Goldplated easy removable input/output contacts Automatic time overlapping for discontinued non-regular yarn movements during start and control time Easy adjustment of the detection sensitivity Goldplated easy removable input/output contacts Detector 8 eyelets with Sub-D connection 9 pins.
![]() | ![]() | ![]() | ![]() |