Frequency Comparator

Next Product »
Yes! I am interested
FOB Price : Get Price

Frequency comparator VCH-308A is intended for precise measuring of frequency and time standards signal instability. The comparator contains built in time interval counter and an interface RS-232C.
Input signals: 1 Hz, 5 MHz, 10 MHz, 100 MHz (0,6 – 1,2V rms).
Maximal input relative frequency difference: (df/f) = ±1x10–6.
Measuring time: t = 1 ms - 105 s.
Passband: 10000Hz, 1000Hz, 10Hz, 3Hz.
Measurement error (frequency instability introduced by the device):
Measuring time t

Main error
(RMS @ df/f=0)
not more
1-100 ms

<3x10–13/t (P = 1000 Hz)
1 s

<7x10–14 (P = 3 Hz)
10 s

<1x10–14 (P = 3 Hz)
100 s

<2x10–15 (P = 3 Hz)
>1000 s

<5x10–16 (P = 3 Hz)
Additional error at df/f: < 2x10-3 df/f.
1 PPS output to the external time interval counter (TTL levels on 50-Ohm load).
Application software (Microsoft Windows 9x,2000,XP):
- Calculates phase and frequency difference of input signals, 2-samples Allan variance, N-samples Allan variance, frequency fluctuations spectra.
- Represents results as tables and plots, stores information in files.
Power: 220 V; 50 - 60 Hz; < 40 VA.
Dimensions: 254x133x311 mm.
Weight: not more 6 kg.

RELATED PRODUCTS
 
X

Invalid Input
Please enter Mobile Number
Invalid Email ID
Invalid Email ID
Your Contact Information
Convenient
Competitive Quotes
Choice of Suppliers
Payment Protection
 
sending enquiry ....

unable to instantiate your call right now. please try after some time.

close

©Copyright HelloTrade.com